• veterianry monitor
  • veterinary monitor 2
  • veterinary monitor 3
  • RM500/RM600 Veterinary Multi-parameter Monitor
  • rwd monitor

RM500/RM600 Veterinary Multi-parameter Monitor

Introducing the ultra-slim compact design, RM500/RM600 veterinary monitor provides an optimized operation experience for veterinary technicians. Together with clinical-originated technologies and accessories, the RM500/RM600 veterinary monitor fulfills your primary requirements in various sceneries for vet patients. Monitorable parameters include SpO₂, ECG, NIBP, TEMP, RESP, ETCO₂

Technical Specifications

  • Features
  • Technical Specifications
  • Order Codes

1.Monitoring parameters displayed in large fonts for easy observation and data recording

2.Streamlined handle design, lightweight and portable

3.ECG:Customized filter for better ECG waves and measurements;Auto-detection of 33 types of arrhythmias

4.SpO2 :Outstanding motion resistance and weak perfusion resistance performance.

  1. Sidestream EtCO2: Superior water trap design, prevent monitor from humidity and damage. Algorithm with intelligent CO2 pseudo wave identification.
  2. Built-in recorder(optional), easy to print
  3. No-fan design brings no noise to the environment.
Size 236×147×236mm
Weight <2.4kg
Display 8″Color LCD, Resolution 800×600
Battery Standard:2550mAh;≥4h

Optional:5100mAh;≥8h

 

Recorder(optional) Number of waveform channels: maximum 3;

Run at the rate of 12.5mm/s, 25mm/s and 50mm/s

ECG Lead type:3 lead

Heart rate range: 15~350bpm; Accuracy: ±1% or 1 bpm, whichever is greater

SpO2 SpO2 Range:0~100%

Revolution:1%

PI Range:0-10, invalid PI value is 0

Data Update Period:1s

NIBP Measurement method: Automatic oscillometry

Working mode: Single (manual), cycle (automatic), fast(continuous)

Measuring Range:

Big Cuff Mode:  SYS: 25 mmHg to 290 mmHg

DIA: 10 mmHg to 250 mmHg

MAP: 15 mmHg to 260 mmHg

Middle Cuff Mode: SYS: 25 mmHg to 240 mmHg

DIA: 10 mmHg to 200 mmHg

MAP: 15 mmHg to 215 mmHg

Small Cuff Mode: SYS: 25 mmHg to 140 mmHg

DIA: 10 mmHg to 115 mmHg

MAP: 15 mmHg to 125 mmHg

RESP Method:Impedance between RA-LL, RA-LA

RR Measuring Range: 0 rpm to150 rpm

Accuracy: 6 rpm to 150 rpm: 2 rpm;0 rpm to 5 rpm: not specified

TEMP Channel:1

Measuring Range: 0 C to 50 C (32 ºF to 122 ºF)

Resolution:0.1℃(0.1 ºF)

EtCO2 Measuring Range :0 mmHg to 150 mmHg (0 % to 20%)

Sample Gas

Measurement mode: Sidestream

Flowrate :50 ml/min, 70 ml/min or 100 ml/min (default), accuracy: 15 ml/min

Model Description
RM500 Veterinary Monitor with SpO2,ECG,RESP,HR,NIBP and TEMP
RM600 Veterinary Monitor with SpO2,ECG,RESP,HR,NIBP,TEMP and EtCO2(Sidestream)

Related Products

  • r630Anesthesia Machine

    R630 Dual Vaporizers Veterinary Anesthesia Machine

    view more >>
  • r620-s1Anesthesia Machine

    R620-S1 Veterinary Inhalation Anesthesia Machine

    view more >>
  • R420 ventilator 03 1

    R420 Veterinary Electric Turbo Ventilator

    view more >>

Have Any Questions?

Send Us A Message

  • 1.Fill in the form and our experts will get back to you ASAP!
  • 2.Ask about An Equipment
  • 3.Wondering which equipment to conduct your researches or perform your experiments? Our sales reps will try their best to share their knowledge with you!
  • 4.Get Technical Support
  • 5.An RWD equipment is not performing? Talk to our support team to get instant feedback!

Contact Us

Top